# CODESYS

**URL:** https://www.wago.community/c/codesys/8.md

[Latest](https://www.wago.community/latest.md) · [Categories](https://www.wago.community/categories.md) · [Tags](https://www.wago.community/tags.md)

---

## [About the CODESYS category](https://www.wago.community/t/about-the-codesys-category/24)

<div class="topic-metadata">

**Author:** [@tyrone.visser](https://www.wago.community/u/tyrone.visser)\
**Replies:** 0\
**Last updated:** [March 15, 2022, 10:40pm UTC](https://www.wago.community/t/about-the-codesys-category/24 "2022-03-15T22:40:09Z")

</div>

A category for sharing projects, code snippets, tips, and best practices working with CODESYS.

---

## [PFC200 (750-8212) OPC UA Data Source drops connection with 0x80AD0000 although server responds normally](https://www.wago.community/t/pfc200-750-8212-opc-ua-data-source-drops-connection-with-0x80ad0000-although-server-responds-normally/2940)

<div class="topic-metadata">

**Author:** [@SigurdRB](https://www.wago.community/u/SigurdRB)\
**Replies:** 0\
**Last updated:** [November 6, 2026, 11:33am UTC](https://www.wago.community/t/pfc200-750-8212-opc-ua-data-source-drops-connection-with-0x80ad0000-although-server-responds-normally/2940 "2026-11-06T11:33:48Z")

</div>

Hello, We use the CODESYS OPC UA Data Source (Data Source Manager) on a PFC200 to connect to three external OPC UA servers. Each connection drops at random intervals, roughly every 1 to 3 hours per connection, and recon…

---

## [PFC100G2 750-8112 Version 6.4.6.4 not in device catalog (only 6.4.6.11 available)](https://www.wago.community/t/pfc100g2-750-8112-version-6-4-6-4-nicht-im-geratekatalog-nur-6-4-6-11-verfugbar/2927)

<div class="topic-metadata">

**Author:** [@MAD2026](https://www.wago.community/u/MAD2026)\
**Replies:** 2\
**Last updated:** [November 5, 2026, 12:40pm UTC](https://www.wago.community/t/pfc100g2-750-8112-version-6-4-6-4-nicht-im-geratekatalog-nur-6-4-6-11-verfugbar/2927 "2026-11-05T12:40:31Z")

</div>

Hi everyone, As mentioned, I need version 6.4.6.4 for the PFC for project planning purposes. Where can I download it (and which repository is it from??)? Unfortunately, I couldn't find 6.4.6.4 in the descriptions. …

---

## [WAGO PLC Firmware vs. CODESYS 3.5 & Device Description: Version Compatibility Guide](https://www.wago.community/t/wago-plc-firmware-vs-codesys-3-5-device-description-version-compatibility-guide/1567)

<div class="topic-metadata">

**Author:** [@Jacob](https://www.wago.community/u/Jacob)\
**Replies:** 8\
**Last updated:** [November 4, 2026, 11:10am UTC](https://www.wago.community/t/wago-plc-firmware-vs-codesys-3-5-device-description-version-compatibility-guide/1567 "2026-11-04T11:10:19Z")

</div>

To program and operate your WAGO PLC correctly, the PLC firmware, CODESYS 3.5 version, and WAGO Device Description must all be compatible. The firmware is the system software that enables the PLC to function, CODESYS is …

---

## [Auto Run Application](https://www.wago.community/t/auto-run-application/2938)

<div class="topic-metadata">

**Author:** [@ValiantSailor](https://www.wago.community/u/ValiantSailor)\
**Replies:** 1\
**Last updated:** [November 4, 2026, 9:57am UTC](https://www.wago.community/t/auto-run-application/2938 "2026-11-04T09:57:01Z")

</div>

Hej, I am trying to write a code to auto restart the application after cold restart. I cannot find a command for this in the libraries and was therefore trying to use startprg shell command, but this does not work eithe…

---

## [CODESYS V3.5 SP21 Patch 1 \[Fatal Error\]](https://www.wago.community/t/codesys-v3-5-sp21-patch-1-fatal-error/2041)

<div class="topic-metadata">

**Author:** [@TomasD](https://www.wago.community/u/TomasD)\
**Replies:** 12\
**Last updated:** [October 30, 2026, 6:54am UTC](https://www.wago.community/t/codesys-v3-5-sp21-patch-1-fatal-error/2041 "2026-10-30T06:54:02Z")

</div>

Good afternoon, updated the controller (FW29) and installed the new environment of Codesys V3.5 SP21.1. After adding visualization, three mistakes pop up: \[Fatal Error\] UNEXPECTED Link: ‘CodemgetContentByfirmCode3’ \[F…

---

## [Codesys language change for visudialogs](https://www.wago.community/t/codesys-language-change-for-visudialogs/2936)

<div class="topic-metadata">

**Author:** [@tn7231](https://www.wago.community/u/tn7231)\
**Replies:** 1\
**Last updated:** [October 29, 2026, 2:47pm UTC](https://www.wago.community/t/codesys-language-change-for-visudialogs/2936 "2026-10-29T14:47:12Z")

</div>

Hi all, I have a project in Codesys 3.5 SP22 P1 running Visudialogs 4.10.0.0 on my PFC300 + WP400. I added language support and currently have German and English with more languages to be added later. I was able to add …

---

## [Web browser to display PDF or HTML file](https://www.wago.community/t/web-browser-to-display-pdf-or-html-file/2578)

<div class="topic-metadata">

**Author:** [@tn7231](https://www.wago.community/u/tn7231)\
**Replies:** 4\
**Last updated:** [October 29, 2026, 8:00am UTC](https://www.wago.community/t/web-browser-to-display-pdf-or-html-file/2578 "2026-10-29T08:00:50Z")

</div>

Hi All, I have a HTML help file that I created and would like to make it possible to open this in one of my webvisu screens on a web panel running the main visualization. I was trying to use the web browser element on a…

---

## [Codesys 4 with WAGO devices](https://www.wago.community/t/codesys-4-with-wago-devices/2921)

<div class="topic-metadata">

**Author:** [@jgovek](https://www.wago.community/u/jgovek)\
**Replies:** 2\
**Last updated:** [October 27, 2026, 8:09pm UTC](https://www.wago.community/t/codesys-4-with-wago-devices/2921 "2026-10-27T20:09:53Z")

</div>

We are starting to get questions about Codesys 4 with WAGO devices. As of right now, WAGO Device and Libraries descriptions have NOT been ported to Codesys 4. I am currently testing Codesys Control for Linux SL with our…

---

## [Softmotion lite library with EtherCAT servo and CC100](https://www.wago.community/t/softmotion-lite-library-with-ethercat-servo-and-cc100/2931)

<div class="topic-metadata">

**Author:** [@JordanMKE](https://www.wago.community/u/JordanMKE)\
**Replies:** 0\
**Last updated:** [October 26, 2026, 4:09pm UTC](https://www.wago.community/t/softmotion-lite-library-with-ethercat-servo-and-cc100/2931 "2026-10-26T16:09:39Z")

</div>

Hi everyone, I have a problem with a simple motion program I’m working on and I’m hoping someone can point me in the correct direction. Hardware: PLC: Wago CC100 (751-9301) Servo drive: Stepperonline A6 EtherCAT (pai…

---

## [Title: PFC300 + 750-652: Modbus RTU communication works only after manually disabling Continuous Send](https://www.wago.community/t/titre-pfc300-750-652-communication-modbus-rtu-fonctionnelle-uniquement-apres-desactivation-manuelle-de-continuous-send/2926)

<div class="topic-metadata">

**Author:** [@lpellicier](https://www.wago.community/u/lpellicier)\
**Replies:** 1\
**Last updated:** [October 26, 2026, 12:58pm UTC](https://www.wago.community/t/titre-pfc300-750-652-communication-modbus-rtu-fonctionnelle-uniquement-apres-desactivation-manuelle-de-continuous-send/2926 "2026-10-26T12:58:16Z")

</div>

Hello, I am using a PFC300 with a serial card 750-652 as a Modbus RTU server. My program simulates an Eurotherm regulator to communicate with Instron Temperature Configurator. The communication works with Doc…

---

## [GetScaledProcessValue](https://www.wago.community/t/getscaledprocessvalue/2928)

<div class="topic-metadata">

**Author:** [@ValiantSailor](https://www.wago.community/u/ValiantSailor)\
**Replies:** 0\
**Last updated:** [October 25, 2026, 6:29pm UTC](https://www.wago.community/t/getscaledprocessvalue/2928 "2026-10-25T18:29:26Z")

</div>

Hej, So I am trying to figure out how to connect the getscaledprocessvalue and diagnostics to what I call xSlot : WagoTypesModule\_750\_450.I\_Module\_750\_450. I know it must be a dynConfig, which is why I added xPort, but …

---

## [How To: Use security certificates with OPC-UA](https://www.wago.community/t/how-to-use-security-certificates-with-opc-ua/2922)

<div class="topic-metadata">

**Author:** [@jgovek](https://www.wago.community/u/jgovek)\
**Replies:** 0\
**Last updated:** [October 22, 2026, 4:31pm UTC](https://www.wago.community/t/how-to-use-security-certificates-with-opc-ua/2922 "2026-10-22T16:31:50Z")

</div>

Excellent walk-thru videos from WAGO Germany that go thru setting up security certificates for OPC-UA on WAGO devices: OPC UA in CODESYS 3.5 #3 | Creating Security Certificates in CODEYS 3.5 OPC UA in CODESYS 3.5 #4 | …

---

## [Wago 750-880 Codesys software](https://www.wago.community/t/wago-750-880-codesys-software/2918)

<div class="topic-metadata">

**Author:** [@aminor85](https://www.wago.community/u/aminor85)\
**Replies:** 1\
**Last updated:** [October 21, 2026, 12:34pm UTC](https://www.wago.community/t/wago-750-880-codesys-software/2918 "2026-10-21T12:34:38Z")

</div>

I am trying to find the CODESYS 2.3 software for the 750-880 but have not been able to find it. I tried the target files but could not get that to work. Does anyone know who I can reach out to?

---

## [BACnet Values Not Updating in WebVisu](https://www.wago.community/t/bacnet-values-not-updating-in-webvisu/2911)

<div class="topic-metadata">

**Author:** [@Vaishnavi](https://www.wago.community/u/Vaishnavi)\
**Replies:** 9\
**Last updated:** [October 20, 2026, 9:47am UTC](https://www.wago.community/t/bacnet-values-not-updating-in-webvisu/2911 "2026-10-20T09:47:23Z")

</div>

Controller: WAGO PFC100 – 750-8112 Firmware: 31 BACnet licence: Enabled Daikin DBACS for air conditioners I am using WAGO BACnet Configurator to transfer data from Daikin to the PFC100 so I can monitor and …

---

## [Have 6.4.5.11, need 6.4.6.4](https://www.wago.community/t/have-6-4-5-11-need-6-4-6-4/2908)

<div class="topic-metadata">

**Author:** [@RobZilla](https://www.wago.community/u/RobZilla)\
**Replies:** 1\
**Last updated:** [October 16, 2026, 6:16pm UTC](https://www.wago.community/t/have-6-4-5-11-need-6-4-6-4/2908 "2026-10-16T18:16:34Z")

</div>

My project uses 6.4.5.11; the panel firmware 04.09.01(31) needs 6.4.6.4. This PC has 6.4.6.11 but not 6.4.6.4. Where can I get it? Did I jump too quick on 3.5SP22P1?

---

## [Error message during online change](https://www.wago.community/t/fehlermeldung-bei-onlinechange/2824)

<div class="topic-metadata">

**Author:** [@radar17892](https://www.wago.community/u/radar17892)\
**Replies:** 8\
**Last updated:** [October 16, 2026, 1:46pm UTC](https://www.wago.community/t/fehlermeldung-bei-onlinechange/2824 "2026-10-16T13:46:20Z")

</div>

Hello, Can someone tell me about this error message: Device message: “Alarm online change executed but license for Online Configuration Change not aviable!” I was still working on this controller last week …

---

## [Read 750-555 status bytes](https://www.wago.community/t/750-555-statusbytes-auslesen/2902)

<div class="topic-metadata">

**Author:** [@pmolke](https://www.wago.community/u/pmolke)\
**Replies:** 3\
**Last updated:** [October 15, 2026, 8:29pm UTC](https://www.wago.community/t/750-555-statusbytes-auslesen/2902 "2026-10-15T20:29:04Z")

</div>

Hey, Does anyone know how to access the status bytes of the terminals in Codesys? I specifically want to detect wire breakage here. Thank you very much.

---

## [Configuration 750-1652 using codesys v3.5 programming](https://www.wago.community/t/configuration-750-1652-using-codesys-v3-5-programming/2905)

<div class="topic-metadata">

**Author:** [@ketan](https://www.wago.community/u/ketan)\
**Replies:** 2\
**Last updated:** [October 15, 2026, 9:25am UTC](https://www.wago.community/t/configuration-750-1652-using-codesys-v3-5-programming/2905 "2026-10-15T09:25:53Z")

</div>

hi.. can we configuration 750-1652 using codesys v3.5 programming? like baudrate, parity, stop bit etc. right now we use Wago IO-Check software for configuration. we want to configure 750-1652 via codesys programming. s…

---

## [Wago PFC unexplained issue](https://www.wago.community/t/wago-pfc-unexplained-issue/2898)

<div class="topic-metadata">

**Author:** [@lukasz19](https://www.wago.community/u/lukasz19)\
**Replies:** 6\
**Last updated:** [October 15, 2026, 9:02am UTC](https://www.wago.community/t/wago-pfc-unexplained-issue/2898 "2026-10-15T09:02:06Z")

</div>

Hello, We’re experiencing an unexplained issue with several PFC200 controllers. We connect to them remotely via VPN. On several occasions, after uploading an application remotely, the download failed at 99%, and the tr…

---

## [Using Ports on the 750-8208 Controller: CAN, CANopen, and PROFIBUS Master](https://www.wago.community/t/using-ports-on-the-750-8208-controller-can-canopen-and-profibus-master/2899)

<div class="topic-metadata">

**Author:** [@TomasD](https://www.wago.community/u/TomasD)\
**Replies:** 1\
**Last updated:** [October 15, 2026, 8:45am UTC](https://www.wago.community/t/using-ports-on-the-750-8208-controller-can-canopen-and-profibus-master/2899 "2026-10-15T08:45:06Z")

</div>

I wasn’t sure exactly where to post this—under “hardware” or “codesys.” I chose Codesys. I have a PLC 750-8208 with firmware version 19, an older but functional version. I purchased a license and installed “Codesys Con…

---

## [Using Modbus Master and ModbusEthernet\_04.lib at the same time](https://www.wago.community/t/using-modbus-master-and-modbusethernet-04-lib-at-the-same-time/2900)

<div class="topic-metadata">

**Author:** [@Yevhen\_ea](https://www.wago.community/u/Yevhen_ea)\
**Replies:** 1\
**Last updated:** [October 15, 2026, 8:43am UTC](https://www.wago.community/t/using-modbus-master-and-modbusethernet-04-lib-at-the-same-time/2900 "2026-10-15T08:43:35Z")

</div>

Hi, on Wago 750-890 & Codesys 2.3, I met the following issue: I needed specific config to make 750-… a modbus tcp server on its reserved I/O memory range, so I sw off the internal Modbus Server on 502 port and used Modb…

---

## [Modbus tcp server on different ports, 750-899](https://www.wago.community/t/modbus-tcp-server-on-different-ports-750-899/2858)

<div class="topic-metadata">

**Author:** [@Yevhen\_ea](https://www.wago.community/u/Yevhen_ea)\
**Replies:** 6\
**Last updated:** [October 6, 2026, 8:28am UTC](https://www.wago.community/t/modbus-tcp-server-on-different-ports-750-899/2858 "2026-10-06T08:28:49Z")

</div>

Hello everyone, Which library do I need for my 750-899/… PLC if I want to listen different ports for Modbus TCP requests. The point is internal modbus server process all requests on 502 port, while I need to discrimina…

---

## [Accessing the CC100 RS-485 interfaces from Linux while CODESYS is using them](https://www.wago.community/t/accessing-the-cc100-rs-485-interfaces-from-linux-while-codesys-is-using-them/2870)

<div class="topic-metadata">

**Author:** [@HANIBAL](https://www.wago.community/u/HANIBAL)\
**Replies:** 9\
**Last updated:** [October 6, 2026, 6:38am UTC](https://www.wago.community/t/accessing-the-cc100-rs-485-interfaces-from-linux-while-codesys-is-using-them/2870 "2026-10-06T06:38:28Z")

</div>

We are developing an application on a WAGO CC100 (751-9402) using CODESYS V3.5. The controller has two RS-485 interfaces, both currently used by the CODESYS application for Modbus RTU communication. We would like to occ…

---

## [How to log data to CSV on CC100 SD Card](https://www.wago.community/t/how-to-log-data-to-csv-on-cc100-sd-card/2328)

<div class="topic-metadata">

**Author:** [@WagoKurt](https://www.wago.community/u/WagoKurt)\
**Replies:** 12\
**Last updated:** [October 5, 2026, 12:13pm UTC](https://www.wago.community/t/how-to-log-data-to-csv-on-cc100-sd-card/2328 "2026-10-05T12:13:45Z")

</div>

This simple example makes use of Coesys 3.5 Libraries, SysFile, SysTypes and SysTimeRtc to datalog every second to a CSV file on an SD Card. This will create a new file when the xRunning variable becomes TRUE. The form…

---

## [WAGO PFC200 (750-8110) – Multiple MQTT Broker Connections](https://www.wago.community/t/wago-pfc200-750-8110-multiple-mqtt-broker-connections/2897)

<div class="topic-metadata">

**Author:** [@Mehak\_Fatima](https://www.wago.community/u/Mehak_Fatima)\
**Replies:** 0\
**Last updated:** [October 3, 2026, 6:54am UTC](https://www.wago.community/t/wago-pfc200-750-8110-multiple-mqtt-broker-connections/2897 "2026-10-03T06:54:16Z")

</div>

Hello, I am currently using a WAGO PFC200 750-8110 for data monitoring and sending data to the cloud through an AWS MQTT broker (Connection 1). I now have a requirement to send the same data to another MQTT broker (Con…

---

## [Runtime received SIGABRT - system may be in an inconsistent state on 750-8212](https://www.wago.community/t/runtime-received-sigabrt-system-may-be-in-an-inconsistent-state-on-750-8212/2868)

<div class="topic-metadata">

**Author:** [@Stonehouse204](https://www.wago.community/u/Stonehouse204)\
**Replies:** 18\
**Last updated:** [October 1, 2026, 8:33am UTC](https://www.wago.community/t/runtime-received-sigabrt-system-may-be-in-an-inconsistent-state-on-750-8212/2868 "2026-10-01T08:33:39Z")

</div>

Hi everyone This error runtime received "SIGABRT - system may be in an inconsistent state "keeps popping up in CODESYS .Only recent ,for some reason .The PFC keeps running and no problems seem to appear in prg or HMI P…

---

## [BACnet Remote Devices Best Practice](https://www.wago.community/t/bacnet-remote-devices-best-practice/2885)

<div class="topic-metadata">

**Author:** [@xxyzz](https://www.wago.community/u/xxyzz)\
**Replies:** 1\
**Last updated:** [October 1, 2026, 8:31am UTC](https://www.wago.community/t/bacnet-remote-devices-best-practice/2885 "2026-10-01T08:31:42Z")

</div>

Hi everyone, I am currently preparing a proof of concept for working with WAGO and BACnet. While working with remote BACnet devices, I came across a few questions regarding the recommended way of interacting with remot…

---

## [WAGO Process Image](https://www.wago.community/t/wago-process-image/2883)

<div class="topic-metadata">

**Author:** [@ValiantSailor](https://www.wago.community/u/ValiantSailor)\
**Replies:** 2\
**Last updated:** [September 30, 2026, 3:49pm UTC](https://www.wago.community/t/wago-process-image/2883 "2026-09-30T15:49:10Z")

</div>

Hej, I am trying to figure out how to built a standard block in Codesys (new to this) and Wago’s documentation isn’t the best. I have a list of channels and want to use the same FB for all channel configurations. The th…

---

## [Modbus - 750-460 configuration by codesys](https://www.wago.community/t/modbus-750-460-configuration-by-codesys/2889)

<div class="topic-metadata">

**Author:** [@lorenzo](https://www.wago.community/u/lorenzo)\
**Replies:** 11\
**Last updated:** [September 28, 2026, 7:40am UTC](https://www.wago.community/t/modbus-750-460-configuration-by-codesys/2889 "2026-09-28T07:40:47Z")

</div>

Hello everyone, I have a 750-469/0003-000 thermocouple module connected to a 750-362 Modbus coupler, which is in turn connected to a PFC300 (FW31). I need to read Type J thermocouples, so I have to change the module’s …

[Next page](https://www.wago.community/c/codesys/8.md?page=1)