## [A complete PLC shutdown due to OPC UA?](https://www.wago.community/t/a-complete-plc-shutdown-due-to-opc-ua/2888)

<div class="topic-metadata">

**Author:** [@TomasD](https://www.wago.community/u/TomasD)\
**Replies:** 2\
**Last updated:** [September 22, 2026, 2:00pm UTC](https://www.wago.community/t/a-complete-plc-shutdown-due-to-opc-ua/2888 "2026-09-22T14:00:03Z")

</div>

I’ve run into this problem (not for the first time) where my PLC freezes, and the only thing that helps is a reboot. I found the following in the logs: runtime.log.1 Sep 22 09:16:26 localhost codesys3: CmpOPCUAStack D…

---

## [Running a custom HTML site / connecting PLC tags to HTML](https://www.wago.community/t/running-a-custom-html-site-connecting-plc-tags-to-html/2877)

<div class="topic-metadata">

**Author:** [@CuriousFox32](https://www.wago.community/u/CuriousFox32)\
**Replies:** 6\
**Last updated:** [September 21, 2026, 11:47am UTC](https://www.wago.community/t/running-a-custom-html-site-connecting-plc-tags-to-html/2877 "2026-09-21T11:47:53Z")

</div>

Hello, I am curious if anyone has found an easier way to run a web application through HTML rather than webvisu? from what I can see, I would most likely need to create a custom HTML where I would need to remake my obje…

---

## [How to configure and program a 750-670 Stepper Controller](https://www.wago.community/t/how-to-configure-and-program-a-750-670-stepper-controller/2880)

<div class="topic-metadata">

**Author:** [@MKNTF](https://www.wago.community/u/MKNTF)\
**Replies:** 3\
**Last updated:** [September 18, 2026, 1:00pm UTC](https://www.wago.community/t/how-to-configure-and-program-a-750-670-stepper-controller/2880 "2026-09-18T13:00:02Z")

</div>

Hello, I am writing to request assistance in preparing to program the WAGO 750-670 stepper motor controller using Structured Text (ST). I would like to develop a program that enables proper configuration and control of…

---

## [Return Module and Channel from Variable](https://www.wago.community/t/return-module-and-channel-from-variable/2873)

<div class="topic-metadata">

**Author:** [@ValiantSailor](https://www.wago.community/u/ValiantSailor)\
**Replies:** 4\
**Last updated:** [September 17, 2026, 9:29am UTC](https://www.wago.community/t/return-module-and-channel-from-variable/2873 "2026-09-17T09:29:38Z")

</div>

Hej, So I am a bit new to CodeSys. I am trying to get the module and channel number from a variable, which is used as an input to a function, but cannot find out how this works here. The goal is I select a variable as a…

---

## [HowTo: Use UNION and STRUCT for Modbus Server mapping](https://www.wago.community/t/howto-use-union-and-struct-for-modbus-server-mapping/2876)

<div class="topic-metadata">

**Author:** [@AdamReeve](https://www.wago.community/u/AdamReeve)\
**Replies:** 0\
**Last updated:** [September 16, 2026, 1:42pm UTC](https://www.wago.community/t/howto-use-union-and-struct-for-modbus-server-mapping/2876 "2026-09-16T13:42:45Z")

</div>

One of my most commonly recreated examples for customers recently has been a walkthrough of using UNION and STRUCT DUTs to map Modbus Servers with mixed datatypes (i.e. DINT and REAL values as well as WORD values). Rathe…

---

## [SD Card status =\> CODESYS?](https://www.wago.community/t/sd-card-status-codesys/2840)

<div class="topic-metadata">

**Author:** [@Boettcher](https://www.wago.community/u/Boettcher)\
**Replies:** 5\
**Last updated:** [September 14, 2026, 2:41pm UTC](https://www.wago.community/t/sd-card-status-codesys/2840 "2026-09-14T14:41:50Z")

</div>

My end goal is to create / trigger an alarm to tell the user there is an issue with controller’s SD Card, because we are writing CSV logs there. I am worried about a situation where an SD card is not present (or has fai…

---

## [WebVisu: Login Required When FileTransferServices Is Enabled](https://www.wago.community/t/webvisu-login-required-when-filetransferservices-is-enabled/2846)

<div class="topic-metadata">

**Author:** [@lorenzo](https://www.wago.community/u/lorenzo)\
**Replies:** 6\
**Last updated:** [September 7, 2026, 8:08am UTC](https://www.wago.community/t/webvisu-login-required-when-filetransferservices-is-enabled/2846 "2026-09-07T08:08:29Z")

</div>

Hello everybody, I have a configuration with a PFC300 and a WP400. I need to enable user/password management to prevent unauthorized PLC downloads. At the same time, I have enabled the following setting in the CODESYS…

---

## [WAGO 750-8212 CODESYS TCP Server Works Only While CODESYS Is Running / Boot Application Causes 750-891 Issues](https://www.wago.community/t/wago-750-8212-codesys-tcp-server-works-only-while-codesys-is-running-boot-application-causes-750-891-issues/2862)

<div class="topic-metadata">

**Author:** [@Mani](https://www.wago.community/u/Mani)\
**Replies:** 3\
**Last updated:** [September 7, 2026, 6:36am UTC](https://www.wago.community/t/wago-750-8212-codesys-tcp-server-works-only-while-codesys-is-running-boot-application-causes-750-891-issues/2862 "2026-09-07T06:36:50Z")

</div>

WAGO 750-8212 Custom TCP Server and 750-891 Modbus TCP Coupler – Boot Application Issue Hello, I am working with two WAGO devices: WAGO 750-8212 PFC200 Controller WAGO 750-891 Modbus TCP Coupler Both devi…

---

## [How to read several slaves - Modbus RTU](https://www.wago.community/t/how-to-read-several-slaves-modbus-rtu/2859)

<div class="topic-metadata">

**Author:** [@WagoUser44](https://www.wago.community/u/WagoUser44)\
**Replies:** 6\
**Last updated:** [September 7, 2026, 2:04am UTC](https://www.wago.community/t/how-to-read-several-slaves-modbus-rtu/2859 "2026-09-07T02:04:21Z")

</div>

Bonjour, Comment je peux lire plusieurs slaves ? Pour 1 slave je sais comment faire mais quand il y a en plusieurs comment on fait ? Pour l’id slave 1 c’est bon, mais j’aimerais aussi récupérer les valeurs des id 5 et …

---

## [How we solved secrets/passwords in a WAGO PFC300 (CODESYS) — Bitwarden Secrets Manager via a small bridge](https://www.wago.community/t/how-we-solved-secrets-passwords-in-a-wago-pfc300-codesys-bitwarden-secrets-manager-via-a-small-bridge/2867)

<div class="topic-metadata">

**Author:** [@espenbo](https://www.wago.community/u/espenbo)\
**Replies:** 0\
**Last updated:** [September 5, 2026, 11:55pm UTC](https://www.wago.community/t/how-we-solved-secrets-passwords-in-a-wago-pfc300-codesys-bitwarden-secrets-manager-via-a-small-bridge/2867 "2026-09-05T23:55:40Z")

</div>

I’ve been looking at the problem with passwords/API tokens in a CODESYS PLC project (WAGO PFC300), and I’m curious how others here handle the same thing. The problem: a WAGO PFC300 needs a password to authenticate again…

---

## [765-4501 port configuration query](https://www.wago.community/t/765-4501-port-configuration-query/2864)

<div class="topic-metadata">

**Author:** [@Justin](https://www.wago.community/u/Justin)\
**Replies:** 1\
**Last updated:** [September 3, 2026, 2:29pm UTC](https://www.wago.community/t/765-4501-port-configuration-query/2864 "2026-09-03T14:29:39Z")

</div>

I have a PFC200 (750-8217, FW 04.07.03(29)) connected to a 765-4501 IO-Link master, programmed in Structural Text using CODESYS 3.5 (SP21, Patch 1). The set-up is designed to accommodate various hardware configurations, …

---

## [Codesys 2.3 Library](https://www.wago.community/t/codesys-2-3-library/1755)

<div class="topic-metadata">

**Author:** [@pp0098](https://www.wago.community/u/pp0098)\
**Replies:** 6\
**Last updated:** [August 25, 2026, 3:26pm UTC](https://www.wago.community/t/codesys-2-3-library/1755 "2026-08-25T15:26:00Z")

</div>

I have a controller 750-8208 with programming software codesys v2.3.9.66. I want to read modbus tcp data through FB. When I load the library i.e. ModbusEthernet\_04.lib, the program shows error. Is there a way to upgrade …

---

## [CODESYS 3.5 SMS alarm sender for WAGO PFC300 and Teltonika RutX](https://www.wago.community/t/codesys-3-5-sms-alarm-sender-for-wago-pfc300-and-teltonika-rutx/2855)

<div class="topic-metadata">

**Author:** [@espenbo](https://www.wago.community/u/espenbo)\
**Replies:** 0\
**Last updated:** [August 23, 2026, 7:10pm UTC](https://www.wago.community/t/codesys-3-5-sms-alarm-sender-for-wago-pfc300-and-teltonika-rutx/2855 "2026-08-23T19:10:43Z")

</div>

Sends PLC alarms as SMS through the Teltonika RUTX REST API. Twenty alarm slots with per-alarm text, debounce and recipient selection, plus queue, retry with duplicate protection, rate limiting and token caching. Incl…

---

## [Connect Control Panel with KBus](https://www.wago.community/t/control-panel-mit-kbus-verbinden/2850)

<div class="topic-metadata">

**Author:** [@MHee](https://www.wago.community/u/MHee)\
**Replies:** 2\
**Last updated:** [August 19, 2026, 1:41pm UTC](https://www.wago.community/t/control-panel-mit-kbus-verbinden/2850 "2026-08-19T13:41:07Z")

</div>

Hi, is it possible to connect Control Panel 762-5303 directly to the KBus and the IO cards, or do you have to go via Modbus, for example? Thanks!

---

## [Running Codesys as regular user - "Could not write options file at...." when closing](https://www.wago.community/t/running-codesys-as-regular-user-could-not-write-options-file-at-when-closing/2813)

<div class="topic-metadata">

**Author:** [@BigWhig](https://www.wago.community/u/BigWhig)\
**Replies:** 2\
**Last updated:** [August 19, 2026, 12:04pm UTC](https://www.wago.community/t/running-codesys-as-regular-user-could-not-write-options-file-at-when-closing/2813 "2026-08-19T12:04:48Z")

</div>

Using Codesys 3.5.21.5. Tried installing both by full .exe file and using codesys installer. Installation requires elevation and completes just fine. However when running Codesys and closing the IDE, options-files are no…

---

## [Error in event handler after inserting the WagoAppDatalogger library](https://www.wago.community/t/fehler-event-handler-nach-einfugen-der-bibliothek-wagoappdatalogger/2848)

<div class="topic-metadata">

**Author:** [@radar17892](https://www.wago.community/u/radar17892)\
**Replies:** 0\
**Last updated:** [August 14, 2026, 11:11am UTC](https://www.wago.community/t/fehler-event-handler-nach-einfugen-der-bibliothek-wagoappdatalogger/2848 "2026-08-14T11:11:27Z")

</div>

Hello. We have noticed that if you add the WagoAppDatalogger library to projects where an event exists in the task configuration, the event no longer works or generates error messages. We are using…

---

## [How To: Add BACnet to a WAGO CODESYS project](https://www.wago.community/t/how-to-add-bacnet-to-a-wago-codesys-project/1626)

<div class="topic-metadata">

**Author:** [@AdamReeve](https://www.wago.community/u/AdamReeve)\
**Replies:** 6\
**Last updated:** [August 11, 2026, 5:36am UTC](https://www.wago.community/t/how-to-add-bacnet-to-a-wago-codesys-project/1626 "2026-08-11T05:36:59Z")

</div>

A short guide on how to use BACnet Configurator to add BACnet support to a CODESYS project. How to add BACnet to a WAGO CODESYS project.docx (924.2 KB)

---

## [I can't connect to the 750-8202/040-001](https://www.wago.community/t/i-cant-connect-to-the-750-8202-040-001/2839)

<div class="topic-metadata">

**Author:** [@emregl](https://www.wago.community/u/emregl)\
**Replies:** 6\
**Last updated:** [August 10, 2026, 6:01pm UTC](https://www.wago.community/t/i-cant-connect-to-the-750-8202-040-001/2839 "2026-08-10T18:01:24Z")

</div>

Which programme should I use to connect to a PLC with these specifications? I couldn’t find the WAGO library in Codesys 2.3 e cockpit tamamen kaldırılmış I need to update the firmware for Codesys 3.5, but I’m getting …

---

## [Error during Store and Download on WAGO\_750-831 BACnet controller](https://www.wago.community/t/erreur-lors-du-store-and-download-sur-controleur-wago-750-831-bacnet/2836)

<div class="topic-metadata">

**Author:** [@Albert](https://www.wago.community/u/Albert)\
**Replies:** 1\
**Last updated:** [August 3, 2026, 12:33am UTC](https://www.wago.community/t/erreur-lors-du-store-and-download-sur-controleur-wago-750-831-bacnet/2836 "2026-08-03T00:33:18Z")

</div>

Hello I'm having an issue with BACnet objects. Before, all analog values were zero. I manually added the points in the Mappings Client using the WAGO BACnet Configurator, and then the next day after …

---

## [Looking for WAGO-I/O-PRO (CODESYS V2.3) and Target Support Package for WAGO 750-885](https://www.wago.community/t/looking-for-wago-i-o-pro-codesys-v2-3-and-target-support-package-for-wago-750-885/2833)

<div class="topic-metadata">

**Author:** [@Phiphat](https://www.wago.community/u/Phiphat)\
**Replies:** 1\
**Last updated:** [August 3, 2026, 12:26am UTC](https://www.wago.community/t/looking-for-wago-i-o-pro-codesys-v2-3-and-target-support-package-for-wago-750-885/2833 "2026-08-03T00:26:35Z")

</div>

Hi everyone, We are currently maintaining an existing project that uses a WAGO 750-885 PFC MR ETHERNET controller. Since CODESYS V2.3 is deprecated and no longer directly accessible on the main WAGO Download Center, we…

---

## [How to use the CODESYS V3 Ethernet Driver in the WAGO VP200 HMI](https://www.wago.community/t/how-to-use-the-codesys-v3-ethernet-driver-in-the-wago-vp200-hmi/2649)

<div class="topic-metadata">

**Author:** [@JohnDitter](https://www.wago.community/u/JohnDitter)\
**Replies:** 3\
**Last updated:** [July 29, 2026, 9:44pm UTC](https://www.wago.community/t/how-to-use-the-codesys-v3-ethernet-driver-in-the-wago-vp200-hmi/2649 "2026-07-29T21:44:35Z")

</div>

Starting with Visual Designer version 5.2.2, WAGO VP200 HMI panels support the CODESYS V3 Ethernet driver, alongside a wide range of other communication drivers. This document details the configuration and use of the COD…

---

## [WagoAppSQL\_MySQL library version 1.7.1.1 errors](https://www.wago.community/t/wagoappsql-mysql-library-version-1-7-1-1-errors/2826)

<div class="topic-metadata">

**Author:** [@Justin](https://www.wago.community/u/Justin)\
**Replies:** 0\
**Last updated:** [July 26, 2026, 8:26pm UTC](https://www.wago.community/t/wagoappsql-mysql-library-version-1-7-1-1-errors/2826 "2026-07-26T20:26:04Z")

</div>

I am upgrading code, having shifted from a PFC200 750-8217 (32 bit) to the PFC300 750-8302 (64 bit). For the PFC200 we are using Firmware 04.07.03(29), CODESYS V3.5 SP21 Patch 1, and version 1.6.2.6 of the WagoAppSQL\_My…

---

## [Wago PFC300 (750-8302) and WagoAppSQL\_xxx libs](https://www.wago.community/t/wago-pfc300-750-8302-and-wagoappsql-xxx-libs/2601)

<div class="topic-metadata">

**Author:** [@FPawlak](https://www.wago.community/u/FPawlak)\
**Replies:** 1\
**Last updated:** [July 26, 2026, 8:17pm UTC](https://www.wago.community/t/wago-pfc300-750-8302-and-wagoappsql-xxx-libs/2601 "2026-07-26T20:17:31Z")

</div>

Hi everyone, I have a problem on new PLC PFC300 (750-8302) with WagoAppSQL\_MySQL lib. It looks like it is not compatible with 64bits PLCs. On older PLCs like 750-8212 and 750-8202 it works without problems. I am using …

---

## [Custom Login Dialog](https://www.wago.community/t/custom-login-dialog/2817)

<div class="topic-metadata">

**Author:** [@RodPer18](https://www.wago.community/u/RodPer18)\
**Replies:** 5\
**Last updated:** [July 21, 2026, 10:56am UTC](https://www.wago.community/t/custom-login-dialog/2817 "2026-07-21T10:56:38Z")

</div>

Hi there, is it possible to make my own custom login dialog instead of using the native ugly codesys one? If there is can you explain how? Thanks!

---

## [Need Target files (.trg) and .WDD file for WAGO 750-893 (CODESYS 2.3 & I/O-Check)](https://www.wago.community/t/need-target-files-trg-and-wdd-file-for-wago-750-893-codesys-2-3-i-o-check/2818)

<div class="topic-metadata">

**Author:** [@Paul1](https://www.wago.community/u/Paul1)\
**Replies:** 1\
**Last updated:** [July 20, 2026, 12:24pm UTC](https://www.wago.community/t/need-target-files-trg-and-wdd-file-for-wago-750-893-codesys-2-3-i-o-check/2818 "2026-07-20T12:24:15Z")

</div>

Hello everyone, I am setting up a new engineering laptop and I need to connect to a WAGO 750-893 controller using CODESYS V2.3 and WAGO I/O-Check 3. Unfortunately, I am unable to find the legacy target files on the WA…

---

## [Configuration 750-652 on PLC 750-8111](https://www.wago.community/t/configuration-750-652-on-plc-750-8111/2819)

<div class="topic-metadata">

**Author:** [@DBB26](https://www.wago.community/u/DBB26)\
**Replies:** 2\
**Last updated:** [July 20, 2026, 6:17am UTC](https://www.wago.community/t/configuration-750-652-on-plc-750-8111/2819 "2026-07-20T06:17:25Z")

</div>

Hi all, im new about wago word but not about PLC. Is my first time about programming a WAGO PLC and im founding some problem about the HW configuration. I have a PFC100 750-8111 PLC with 2 modules: 750-1405 and a 750-6…

---

## [Error configuring IO terminal 750\_496\_16](https://www.wago.community/t/fehler-beim-konfigurieren-einer-io-klemme-750-496-16/2815)

<div class="topic-metadata">

**Author:** [@Hannah](https://www.wago.community/u/Hannah)\
**Replies:** 2\
**Last updated:** [July 14, 2026, 8:47am UTC](https://www.wago.community/t/fehler-beim-konfigurieren-einer-io-klemme-750-496-16/2815 "2026-07-14T08:47:51Z")

</div>

Hello everyone, I would like to configure my WAGO terminal (750\_496\_1) via Codesys. I am using the following function to configure my channels: aeChannel\_WagoModul\_750\_496\_SignalType\[1\] := 0; aeChannel\_WagoModu…

---

## [Pass Codesys recipes between two controllers that are not on the same network](https://www.wago.community/t/pass-codesys-recipes-between-two-controllers-that-are-not-on-the-same-network/2795)

<div class="topic-metadata">

**Author:** [@colsen](https://www.wago.community/u/colsen)\
**Replies:** 2\
**Last updated:** [July 13, 2026, 10:25pm UTC](https://www.wago.community/t/pass-codesys-recipes-between-two-controllers-that-are-not-on-the-same-network/2795 "2026-07-13T22:25:29Z")

</div>

Codesys 3.5.21.3 using WebVisu on a CC-100. I have a client that is hoping that he can download a recipe from my recipe manager in one PLC and upload it to another. The two PLCs are not on the same network. My research …

---

## [Missing files when opening a project in codesys](https://www.wago.community/t/missing-files-when-opening-a-project-in-codesys/2812)

<div class="topic-metadata">

**Author:** [@kaushikvishal6999](https://www.wago.community/u/kaushikvishal6999)\
**Replies:** 1\
**Last updated:** [July 13, 2026, 6:45am UTC](https://www.wago.community/t/missing-files-when-opening-a-project-in-codesys/2812 "2026-07-13T06:45:16Z")

</div>

i use Codesys version 3.5 SP19 patch 17. when i try to open a project applicaiton which was sent to me from a colleague, some files in projects are missing inside codesys. How to open a project application without losin…

---

## [CC100 Modbus RTU](https://www.wago.community/t/cc100-modbus-rtu/2796)

<div class="topic-metadata">

**Author:** [@MatthewKim](https://www.wago.community/u/MatthewKim)\
**Replies:** 1\
**Last updated:** [July 6, 2026, 8:12am UTC](https://www.wago.community/t/cc100-modbus-rtu/2796 "2026-07-06T08:12:52Z")

</div>

Hello. This is Matthew Kim from Korea. I would like to contact you because a situation I do not understand occurred while testing the CC100 X11 Modbus RTU. I connected the CC100 X11 via the PC’s USB 485 port. I would …