## [PFC200 (750-8212) OPC UA Data Source drops connection with 0x80AD0000 although server responds normally](https://www.wago.community/t/pfc200-750-8212-opc-ua-data-source-drops-connection-with-0x80ad0000-although-server-responds-normally/2940)

<div class="topic-metadata">

**Author:** [@SigurdRB](https://www.wago.community/u/SigurdRB)\
**Replies:** 0\
**Last updated:** [November 6, 2026, 11:33am UTC](https://www.wago.community/t/pfc200-750-8212-opc-ua-data-source-drops-connection-with-0x80ad0000-although-server-responds-normally/2940 "2026-11-06T11:33:48Z")

</div>

Hello, We use the CODESYS OPC UA Data Source (Data Source Manager) on a PFC200 to connect to three external OPC UA servers. Each connection drops at random intervals, roughly every 1 to 3 hours per connection, and recon…

---

## [PFC100G2 750-8112 Version 6.4.6.4 not in device catalog (only 6.4.6.11 available)](https://www.wago.community/t/pfc100g2-750-8112-version-6-4-6-4-nicht-im-geratekatalog-nur-6-4-6-11-verfugbar/2927)

<div class="topic-metadata">

**Author:** [@MAD2026](https://www.wago.community/u/MAD2026)\
**Replies:** 2\
**Last updated:** [November 5, 2026, 12:40pm UTC](https://www.wago.community/t/pfc100g2-750-8112-version-6-4-6-4-nicht-im-geratekatalog-nur-6-4-6-11-verfugbar/2927 "2026-11-05T12:40:31Z")

</div>

Hi everyone, As mentioned, I need version 6.4.6.4 for the PFC for project planning purposes. Where can I download it (and which repository is it from??)? Unfortunately, I couldn't find 6.4.6.4 in the descriptions. …

---

## [WAGO PLC Firmware vs. CODESYS 3.5 & Device Description: Version Compatibility Guide](https://www.wago.community/t/wago-plc-firmware-vs-codesys-3-5-device-description-version-compatibility-guide/1567)

<div class="topic-metadata">

**Author:** [@Jacob](https://www.wago.community/u/Jacob)\
**Replies:** 8\
**Last updated:** [November 4, 2026, 11:10am UTC](https://www.wago.community/t/wago-plc-firmware-vs-codesys-3-5-device-description-version-compatibility-guide/1567 "2026-11-04T11:10:19Z")

</div>

To program and operate your WAGO PLC correctly, the PLC firmware, CODESYS 3.5 version, and WAGO Device Description must all be compatible. The firmware is the system software that enables the PLC to function, CODESYS is …

---

## [Auto Run Application](https://www.wago.community/t/auto-run-application/2938)

<div class="topic-metadata">

**Author:** [@ValiantSailor](https://www.wago.community/u/ValiantSailor)\
**Replies:** 1\
**Last updated:** [November 4, 2026, 9:57am UTC](https://www.wago.community/t/auto-run-application/2938 "2026-11-04T09:57:01Z")

</div>

Hej, I am trying to write a code to auto restart the application after cold restart. I cannot find a command for this in the libraries and was therefore trying to use startprg shell command, but this does not work eithe…

---

## [Mapping of module data to trend sqlite integer](https://www.wago.community/t/mapping-of-module-data-to-trend-sqlite-integer/2930)

<div class="topic-metadata">

**Author:** [@CoMic](https://www.wago.community/u/CoMic)\
**Replies:** 1\
**Last updated:** [October 30, 2026, 3:58pm UTC](https://www.wago.community/t/mapping-of-module-data-to-trend-sqlite-integer/2930 "2026-10-30T15:58:40Z")

</div>

Hallo, Community Ich möchte die SQLite-DB des Trend Recorders auswerten. Die TimeStamp Werte sind nachvollziehbar und umrechenbar. Für die Kanalwerte gibt DB Browser als Datentyp INT aus, was, wie ich gelesen habe, aus …

---

## [Cybersecurity vulnerability CVE-2026-109618 and CVE-2026-109619](https://www.wago.community/t/cybersecurity-vulnerability-cve-2026-109618-and-cve-2026-109619/2937)

<div class="topic-metadata">

**Author:** [@LotfiH](https://www.wago.community/u/LotfiH)\
**Replies:** 4\
**Last updated:** [October 30, 2026, 3:52pm UTC](https://www.wago.community/t/cybersecurity-vulnerability-cve-2026-109618-and-cve-2026-109619/2937 "2026-10-30T15:52:56Z")

</div>

Hello, Are the PFC100/PFC200 concerned by theses PHP vulerabilities CVE-2026-109619 and CVE-2026-109618 ? Did Wago already published a patch/fix about this for the concerned hardware ? Thank you all,

---

## [CODESYS V3.5 SP21 Patch 1 \[Fatal Error\]](https://www.wago.community/t/codesys-v3-5-sp21-patch-1-fatal-error/2041)

<div class="topic-metadata">

**Author:** [@TomasD](https://www.wago.community/u/TomasD)\
**Replies:** 12\
**Last updated:** [October 30, 2026, 6:54am UTC](https://www.wago.community/t/codesys-v3-5-sp21-patch-1-fatal-error/2041 "2026-10-30T06:54:02Z")

</div>

Good afternoon, updated the controller (FW29) and installed the new environment of Codesys V3.5 SP21.1. After adding visualization, three mistakes pop up: \[Fatal Error\] UNEXPECTED Link: ‘CodemgetContentByfirmCode3’ \[F…

---

## [Codesys language change for visudialogs](https://www.wago.community/t/codesys-language-change-for-visudialogs/2936)

<div class="topic-metadata">

**Author:** [@tn7231](https://www.wago.community/u/tn7231)\
**Replies:** 1\
**Last updated:** [October 29, 2026, 2:47pm UTC](https://www.wago.community/t/codesys-language-change-for-visudialogs/2936 "2026-10-29T14:47:12Z")

</div>

Hi all, I have a project in Codesys 3.5 SP22 P1 running Visudialogs 4.10.0.0 on my PFC300 + WP400. I added language support and currently have German and English with more languages to be added later. I was able to add …

---

## [Web browser to display PDF or HTML file](https://www.wago.community/t/web-browser-to-display-pdf-or-html-file/2578)

<div class="topic-metadata">

**Author:** [@tn7231](https://www.wago.community/u/tn7231)\
**Replies:** 4\
**Last updated:** [October 29, 2026, 8:00am UTC](https://www.wago.community/t/web-browser-to-display-pdf-or-html-file/2578 "2026-10-29T08:00:50Z")

</div>

Hi All, I have a HTML help file that I created and would like to make it possible to open this in one of my webvisu screens on a web panel running the main visualization. I was trying to use the web browser element on a…

---

## [Codesys 4 with WAGO devices](https://www.wago.community/t/codesys-4-with-wago-devices/2921)

<div class="topic-metadata">

**Author:** [@jgovek](https://www.wago.community/u/jgovek)\
**Replies:** 2\
**Last updated:** [October 27, 2026, 8:09pm UTC](https://www.wago.community/t/codesys-4-with-wago-devices/2921 "2026-10-27T20:09:53Z")

</div>

We are starting to get questions about Codesys 4 with WAGO devices. As of right now, WAGO Device and Libraries descriptions have NOT been ported to Codesys 4. I am currently testing Codesys Control for Linux SL with our…

---

## [Softmotion lite library with EtherCAT servo and CC100](https://www.wago.community/t/softmotion-lite-library-with-ethercat-servo-and-cc100/2931)

<div class="topic-metadata">

**Author:** [@JordanMKE](https://www.wago.community/u/JordanMKE)\
**Replies:** 0\
**Last updated:** [October 26, 2026, 4:09pm UTC](https://www.wago.community/t/softmotion-lite-library-with-ethercat-servo-and-cc100/2931 "2026-10-26T16:09:39Z")

</div>

Hi everyone, I have a problem with a simple motion program I’m working on and I’m hoping someone can point me in the correct direction. Hardware: PLC: Wago CC100 (751-9301) Servo drive: Stepperonline A6 EtherCAT (pai…

---

## [Title: PFC300 + 750-652: Modbus RTU communication works only after manually disabling Continuous Send](https://www.wago.community/t/titre-pfc300-750-652-communication-modbus-rtu-fonctionnelle-uniquement-apres-desactivation-manuelle-de-continuous-send/2926)

<div class="topic-metadata">

**Author:** [@lpellicier](https://www.wago.community/u/lpellicier)\
**Replies:** 1\
**Last updated:** [October 26, 2026, 12:58pm UTC](https://www.wago.community/t/titre-pfc300-750-652-communication-modbus-rtu-fonctionnelle-uniquement-apres-desactivation-manuelle-de-continuous-send/2926 "2026-10-26T12:58:16Z")

</div>

Hello, I am using a PFC300 with a serial card 750-652 as a Modbus RTU server. My program simulates an Eurotherm regulator to communicate with Instron Temperature Configurator. The communication works with Doc…

---

## [Parsing JSON with "FbWrite\_ToIEC\_ByRule" - Wago CC100 + Codesys V3](https://www.wago.community/t/json-parsen-mit-fbwrite-toiec-byrule-wago-cc100-codesys-v3/2919)

<div class="topic-metadata">

**Author:** [@FlyingDutchman](https://www.wago.community/u/FlyingDutchman)\
**Replies:** 3\
**Last updated:** [October 25, 2026, 10:48pm UTC](https://www.wago.community/t/json-parsen-mit-fbwrite-toiec-byrule-wago-cc100-codesys-v3/2919 "2026-10-25T22:48:13Z")

</div>

Hello everyone, I have a problem here where I'm not quite sure how to proceed. Maybe someone could give me a hand. An API request was made to retrieve the JSON response from https://api.awattar.at/v1/marketd…

---

## [EKBPRO KNX Terminal Python – an open-source KNX SCADA in the terminal, with an OPC UA bridge to CODESYS on WAGO PFC](https://www.wago.community/t/ekbpro-knx-terminal-python-an-open-source-knx-scada-in-the-terminal-with-an-opc-ua-bridge-to-codesys-on-wago-pfc/2929)

<div class="topic-metadata">

**Author:** [@espenbo](https://www.wago.community/u/espenbo)\
**Replies:** 0\
**Last updated:** [October 25, 2026, 9:04pm UTC](https://www.wago.community/t/ekbpro-knx-terminal-python-an-open-source-knx-scada-in-the-terminal-with-an-opc-ua-bridge-to-codesys-on-wago-pfc/2929 "2026-10-25T21:04:36Z")

</div>

Hi all, I’d like to share an open-source project I’ve been building: \*\*EKBPRO KNX Terminal Python\*\*, a SCADA and visualisation for KNX that runs in the terminal and is used over SSH. It runs in Docker on a WAGO PFC200/P…

---

## [GetScaledProcessValue](https://www.wago.community/t/getscaledprocessvalue/2928)

<div class="topic-metadata">

**Author:** [@ValiantSailor](https://www.wago.community/u/ValiantSailor)\
**Replies:** 0\
**Last updated:** [October 25, 2026, 6:29pm UTC](https://www.wago.community/t/getscaledprocessvalue/2928 "2026-10-25T18:29:26Z")

</div>

Hej, So I am trying to figure out how to connect the getscaledprocessvalue and diagnostics to what I call xSlot : WagoTypesModule\_750\_450.I\_Module\_750\_450. I know it must be a dynConfig, which is why I added xPort, but …

---

## [Virtual IP address in PFC 200/300](https://www.wago.community/t/virtual-ip-address-in-pfc-200-300/2924)

<div class="topic-metadata">

**Author:** [@Maverick88](https://www.wago.community/u/Maverick88)\
**Replies:** 0\
**Last updated:** [October 23, 2026, 10:58am UTC](https://www.wago.community/t/virtual-ip-address-in-pfc-200-300/2924 "2026-10-23T10:58:27Z")

</div>

Hello all, I’m designing a redundant alarm and monitoring system (marine application) and would like advice on how the SCADA side should connect to a redundant PFC200 pair. Setup 2 × PFC200 G2 (750-8210) running CODE…

---

## [WAGO Ethernet Settings Command Line](https://www.wago.community/t/wago-ethernet-settings-command-line/2923)

<div class="topic-metadata">

**Author:** [@pflot59](https://www.wago.community/u/pflot59)\
**Replies:** 0\
**Last updated:** [October 22, 2026, 5:01pm UTC](https://www.wago.community/t/wago-ethernet-settings-command-line/2923 "2026-10-22T17:01:45Z")

</div>

Bonjour Dans le passé on m’avait montré comment lancer Wago Ethernet Settings via un raccourci ou en ligne de commande via un fichier bat, en spécifiant l’adresse IP de l’automate que l’on voulait atteindre. C’est prat…

---

## [How To: Use security certificates with OPC-UA](https://www.wago.community/t/how-to-use-security-certificates-with-opc-ua/2922)

<div class="topic-metadata">

**Author:** [@jgovek](https://www.wago.community/u/jgovek)\
**Replies:** 0\
**Last updated:** [October 22, 2026, 4:31pm UTC](https://www.wago.community/t/how-to-use-security-certificates-with-opc-ua/2922 "2026-10-22T16:31:50Z")

</div>

Excellent walk-thru videos from WAGO Germany that go thru setting up security certificates for OPC-UA on WAGO devices: OPC UA in CODESYS 3.5 #3 | Creating Security Certificates in CODEYS 3.5 OPC UA in CODESYS 3.5 #4 | …

---

## [Critical controller error PFC200](https://www.wago.community/t/critical-controller-error-pfc200/2920)

<div class="topic-metadata">

**Author:** [@lukasz19](https://www.wago.community/u/lukasz19)\
**Replies:** 0\
**Last updated:** [October 22, 2026, 6:45am UTC](https://www.wago.community/t/critical-controller-error-pfc200/2920 "2026-10-22T06:45:36Z")

</div>

Hello, When I load the application into a controller PFC200 that has KBUS and IO modules installed but without those modules, a firmware error occurs. The controller responds to pings, but there is no connectivity via S…

---

## [Wago 750-880 Codesys software](https://www.wago.community/t/wago-750-880-codesys-software/2918)

<div class="topic-metadata">

**Author:** [@aminor85](https://www.wago.community/u/aminor85)\
**Replies:** 1\
**Last updated:** [October 21, 2026, 12:34pm UTC](https://www.wago.community/t/wago-750-880-codesys-software/2918 "2026-10-21T12:34:38Z")

</div>

I am trying to find the CODESYS 2.3 software for the 750-880 but have not been able to find it. I tried the target files but could not get that to work. Does anyone know who I can reach out to?

---

## [BACnet Values Not Updating in WebVisu](https://www.wago.community/t/bacnet-values-not-updating-in-webvisu/2911)

<div class="topic-metadata">

**Author:** [@Vaishnavi](https://www.wago.community/u/Vaishnavi)\
**Replies:** 9\
**Last updated:** [October 20, 2026, 9:47am UTC](https://www.wago.community/t/bacnet-values-not-updating-in-webvisu/2911 "2026-10-20T09:47:23Z")

</div>

Controller: WAGO PFC100 – 750-8112 Firmware: 31 BACnet licence: Enabled Daikin DBACS for air conditioners I am using WAGO BACnet Configurator to transfer data from Daikin to the PFC100 so I can monitor and …

---

## [Have 6.4.5.11, need 6.4.6.4](https://www.wago.community/t/have-6-4-5-11-need-6-4-6-4/2908)

<div class="topic-metadata">

**Author:** [@RobZilla](https://www.wago.community/u/RobZilla)\
**Replies:** 1\
**Last updated:** [October 16, 2026, 6:16pm UTC](https://www.wago.community/t/have-6-4-5-11-need-6-4-6-4/2908 "2026-10-16T18:16:34Z")

</div>

My project uses 6.4.5.11; the panel firmware 04.09.01(31) needs 6.4.6.4. This PC has 6.4.6.11 but not 6.4.6.4. Where can I get it? Did I jump too quick on 3.5SP22P1?

---

## [Error message during online change](https://www.wago.community/t/fehlermeldung-bei-onlinechange/2824)

<div class="topic-metadata">

**Author:** [@radar17892](https://www.wago.community/u/radar17892)\
**Replies:** 8\
**Last updated:** [October 16, 2026, 1:46pm UTC](https://www.wago.community/t/fehlermeldung-bei-onlinechange/2824 "2026-10-16T13:46:20Z")

</div>

Hello, Can someone tell me about this error message: Device message: “Alarm online change executed but license for Online Configuration Change not aviable!” I was still working on this controller last week …

---

## [Read 750-555 status bytes](https://www.wago.community/t/750-555-statusbytes-auslesen/2902)

<div class="topic-metadata">

**Author:** [@pmolke](https://www.wago.community/u/pmolke)\
**Replies:** 3\
**Last updated:** [October 15, 2026, 8:29pm UTC](https://www.wago.community/t/750-555-statusbytes-auslesen/2902 "2026-10-15T20:29:04Z")

</div>

Hey, Does anyone know how to access the status bytes of the terminals in Codesys? I specifically want to detect wire breakage here. Thank you very much.

---

## [Configuration 750-1652 using codesys v3.5 programming](https://www.wago.community/t/configuration-750-1652-using-codesys-v3-5-programming/2905)

<div class="topic-metadata">

**Author:** [@ketan](https://www.wago.community/u/ketan)\
**Replies:** 2\
**Last updated:** [October 15, 2026, 9:25am UTC](https://www.wago.community/t/configuration-750-1652-using-codesys-v3-5-programming/2905 "2026-10-15T09:25:53Z")

</div>

hi.. can we configuration 750-1652 using codesys v3.5 programming? like baudrate, parity, stop bit etc. right now we use Wago IO-Check software for configuration. we want to configure 750-1652 via codesys programming. s…

---

## [Wago PFC unexplained issue](https://www.wago.community/t/wago-pfc-unexplained-issue/2898)

<div class="topic-metadata">

**Author:** [@lukasz19](https://www.wago.community/u/lukasz19)\
**Replies:** 6\
**Last updated:** [October 15, 2026, 9:02am UTC](https://www.wago.community/t/wago-pfc-unexplained-issue/2898 "2026-10-15T09:02:06Z")

</div>

Hello, We’re experiencing an unexplained issue with several PFC200 controllers. We connect to them remotely via VPN. On several occasions, after uploading an application remotely, the download failed at 99%, and the tr…

---

## [Using Ports on the 750-8208 Controller: CAN, CANopen, and PROFIBUS Master](https://www.wago.community/t/using-ports-on-the-750-8208-controller-can-canopen-and-profibus-master/2899)

<div class="topic-metadata">

**Author:** [@TomasD](https://www.wago.community/u/TomasD)\
**Replies:** 1\
**Last updated:** [October 15, 2026, 8:45am UTC](https://www.wago.community/t/using-ports-on-the-750-8208-controller-can-canopen-and-profibus-master/2899 "2026-10-15T08:45:06Z")

</div>

I wasn’t sure exactly where to post this—under “hardware” or “codesys.” I chose Codesys. I have a PLC 750-8208 with firmware version 19, an older but functional version. I purchased a license and installed “Codesys Con…

---

## [Using Modbus Master and ModbusEthernet\_04.lib at the same time](https://www.wago.community/t/using-modbus-master-and-modbusethernet-04-lib-at-the-same-time/2900)

<div class="topic-metadata">

**Author:** [@Yevhen\_ea](https://www.wago.community/u/Yevhen_ea)\
**Replies:** 1\
**Last updated:** [October 15, 2026, 8:43am UTC](https://www.wago.community/t/using-modbus-master-and-modbusethernet-04-lib-at-the-same-time/2900 "2026-10-15T08:43:35Z")

</div>

Hi, on Wago 750-890 & Codesys 2.3, I met the following issue: I needed specific config to make 750-… a modbus tcp server on its reserved I/O memory range, so I sw off the internal Modbus Server on 502 port and used Modb…

---

## [Modbus tcp server on different ports, 750-899](https://www.wago.community/t/modbus-tcp-server-on-different-ports-750-899/2858)

<div class="topic-metadata">

**Author:** [@Yevhen\_ea](https://www.wago.community/u/Yevhen_ea)\
**Replies:** 6\
**Last updated:** [October 6, 2026, 8:28am UTC](https://www.wago.community/t/modbus-tcp-server-on-different-ports-750-899/2858 "2026-10-06T08:28:49Z")

</div>

Hello everyone, Which library do I need for my 750-899/… PLC if I want to listen different ports for Modbus TCP requests. The point is internal modbus server process all requests on 502 port, while I need to discrimina…

---

## [Accessing the CC100 RS-485 interfaces from Linux while CODESYS is using them](https://www.wago.community/t/accessing-the-cc100-rs-485-interfaces-from-linux-while-codesys-is-using-them/2870)

<div class="topic-metadata">

**Author:** [@HANIBAL](https://www.wago.community/u/HANIBAL)\
**Replies:** 9\
**Last updated:** [October 6, 2026, 6:38am UTC](https://www.wago.community/t/accessing-the-cc100-rs-485-interfaces-from-linux-while-codesys-is-using-them/2870 "2026-10-06T06:38:28Z")

</div>

We are developing an application on a WAGO CC100 (751-9402) using CODESYS V3.5. The controller has two RS-485 interfaces, both currently used by the CODESYS application for Modbus RTU communication. We would like to occ…