## [\[OPC UA\] NodeID path changes on Client side (Data Sources Manager) — How to preserve Server-side hierarchy?](https://www.wago.community/t/opc-ua-nodeid-path-changes-on-client-side-data-sources-manager-how-to-preserve-server-side-hierarchy/2754)

<div class="topic-metadata">

**Author:** [@Pattanapong](https://www.wago.community/u/Pattanapong)\
**Replies:** 2\
**Last updated:** [June 30, 2026, 6:06am UTC](https://www.wago.community/t/opc-ua-nodeid-path-changes-on-client-side-data-sources-manager-how-to-preserve-server-side-hierarchy/2754 "2026-06-30T06:06:59Z")

</div>

Hi everyone, I’m working on a small-scale Smart Factory project using CODESYS-based PLCs (WAGO) and running into an OPC UA NodeID naming issue. Hope someone can point me in the right direction. Project Architecture: 5…

---

## [Talk to Your PLC in Plain English: An Open-Source MCP Server for WAGO Devices](https://www.wago.community/t/talk-to-your-plc-in-plain-english-an-open-source-mcp-server-for-wago-devices/2771)

<div class="topic-metadata">

**Author:** [@wagoalex](https://www.wago.community/u/wagoalex)\
**Replies:** 2\
**Last updated:** [June 24, 2026, 12:28pm UTC](https://www.wago.community/t/talk-to-your-plc-in-plain-english-an-open-source-mcp-server-for-wago-devices/2771 "2026-06-24T12:28:10Z")

</div>

If you’ve ever wished you could ask your PLC “which network interfaces are active?” and just get an answer - without looking up parameter IDs, writing a script, or opening the web interface - this project might interest…

---

## [Unstable DMX values (Slave) on WAGO PFC200 (750-8212) with terminal 753-652](https://www.wago.community/t/instabile-dmx-werte-slave-an-wago-pfc200-750-8212-mit-klemme-753-652/2752)

<div class="topic-metadata">

**Author:** [@LucdeKo](https://www.wago.community/u/LucdeKo)\
**Replies:** 2\
**Last updated:** [June 21, 2026, 9:05pm UTC](https://www.wago.community/t/instabile-dmx-werte-slave-an-wago-pfc200-750-8212-mit-klemme-753-652/2752 "2026-06-21T21:05:58Z")

</div>

Hello everyone, for the stage technology in our theater, we have set up a central control system. We are using the following WAGO hardware, which is controlled from the lighting console: Controller: PFC200 (750-8212) …

---

## [How To: Create a self installing SD Card (aka Magic SD)](https://www.wago.community/t/how-to-create-a-self-installing-sd-card-aka-magic-sd/280)

<div class="topic-metadata">

**Author:** [@WagoKurt](https://www.wago.community/u/WagoKurt)\
**Replies:** 9\
**Last updated:** [June 19, 2026, 9:34am UTC](https://www.wago.community/t/how-to-create-a-self-installing-sd-card-aka-magic-sd/280 "2026-06-19T09:34:47Z")

</div>

Steps to create an SD card that when booted, will perform an automatic Firmware Update. Create a bootable sd-card Using a flashing utility (like Balena or WinDiskImager) Using WBM via Administration\>Create Image B…

---

## [Zeroconf on WAGO Controller](https://www.wago.community/t/zeroconf-on-wago-controller/2444)

<div class="topic-metadata">

**Author:** [@quenorha](https://www.wago.community/u/quenorha)\
**Replies:** 5\
**Last updated:** [April 30, 2026, 7:34pm UTC](https://www.wago.community/t/zeroconf-on-wago-controller/2444 "2026-04-30T19:34:00Z")

</div>

You may have already used Zeroconf technology and mDNS without realizing it. It allows you to automatically assign a hostname of the type .local to a machine without configuring DNS, making it easy to access without kno…

---

## [CC 100 OpenVPN Configuration via SSH](https://www.wago.community/t/cc-100-openvpn-configuration-via-ssh/2655)

<div class="topic-metadata">

**Author:** [@Dr.Fix](https://www.wago.community/u/Dr.Fix)\
**Replies:** 2\
**Last updated:** [April 1, 2026, 1:47pm UTC](https://www.wago.community/t/cc-100-openvpn-configuration-via-ssh/2655 "2026-04-01T13:47:32Z")

</div>

Hello everyone, We are already using OpenVPN with the CC100. With the additional information from this forum and the YouTube how-to video (https://www.youtube.com/watch?v=H4c7NQiCalk) regarding the extra OVPN config lin…

---

## [Remotely Capturing Network Traffic on PFC using Wireshark](https://www.wago.community/t/remotely-capturing-network-traffic-on-pfc-using-wireshark/2614)

<div class="topic-metadata">

**Author:** [@Wago\_Hunter](https://www.wago.community/u/Wago_Hunter)\
**Replies:** 6\
**Last updated:** [March 10, 2026, 5:24pm UTC](https://www.wago.community/t/remotely-capturing-network-traffic-on-pfc-using-wireshark/2614 "2026-03-10T17:24:26Z")

</div>

By utilizing the tcpdump library included in Wago PFC controllers (as well as Edge Controllers and Edge Computers), it is possible to capture network traffic in & out of the Wago controllers in Wireshark without the need…

---

## [Tech Note: 3S Runtime with OPC UA Server](https://www.wago.community/t/tech-note-3s-runtime-with-opc-ua-server/305)

<div class="topic-metadata">

**Author:** [@MikePsaltis](https://www.wago.community/u/MikePsaltis)\
**Replies:** 43\
**Last updated:** [January 22, 2026, 3:02pm UTC](https://www.wago.community/t/tech-note-3s-runtime-with-opc-ua-server/305 "2026-01-22T15:02:35Z")

</div>

\---- The following note only pertains to devices with the CODESYS target from 3S ---- When using the 3S target for the Codesys Store, the runtime has an embeded OPC UA server that is independent of the WAGO OPC UA serve…

---

## [WAGO PLC EDGE Control not responding to devicebound commands from Azure IoT Hub](https://www.wago.community/t/wago-plc-edge-control-not-responding-to-devicebound-commands-from-azure-iot-hub/2412)

<div class="topic-metadata">

**Author:** [@isabela.brandao](https://www.wago.community/u/isabela.brandao)\
**Replies:** 0\
**Last updated:** [November 14, 2025, 6:54am UTC](https://www.wago.community/t/wago-plc-edge-control-not-responding-to-devicebound-commands-from-azure-iot-hub/2412 "2025-11-14T06:54:06Z")

</div>

Hello WAGO Community :waving\_hand: I’m currently integrating a WAGO PLC with Azure IoT Hub via MQTT over TLS 1.2, and I’m experiencing an issue with cloud-to-device communication. Here’s the situation: The PLC conne…

---

## [DNP3 Telecontrol Change Slave Target in Runtime](https://www.wago.community/t/dnp3-telecontrol-change-slave-target-in-runtime/2363)

<div class="topic-metadata">

**Author:** [@czek](https://www.wago.community/u/czek)\
**Replies:** 0\
**Last updated:** [October 17, 2025, 1:40pm UTC](https://www.wago.community/t/dnp3-telecontrol-change-slave-target-in-runtime/2363 "2025-10-17T13:40:11Z")

</div>

Hello, I am using an edge-controller (752-8303), codesys 3.5 SP21.1, and WAGO Runtime DNP3 Master License L. I can successfully connect to my target DNP3 Slave but am wondering if it is possible to view and change the cu…

---

## [WAGO Controller REST:API](https://www.wago.community/t/wago-controller-rest-api/663)

<div class="topic-metadata">

**Author:** [@Michael](https://www.wago.community/u/Michael)\
**Replies:** 12\
**Last updated:** [August 18, 2025, 2:20pm UTC](https://www.wago.community/t/wago-controller-rest-api/663 "2025-08-18T14:20:31Z")

</div>

Linux Based Wago Controllers offer an REST:API to read/write different settings of WBM. you’ll find the API description on your contoller at: http://IP/openapi/wda.openapi.html#section/REST-API-Overview you will find tw…

---

## [OPCUA Datasource setup in codesys Error in OPC UA call BadCommunicationError](https://www.wago.community/t/opcua-datasource-setup-in-codesys-error-in-opc-ua-call-badcommunicationerror/2111)

<div class="topic-metadata">

**Author:** [@Varshag](https://www.wago.community/u/Varshag)\
**Replies:** 8\
**Last updated:** [August 4, 2025, 8:11am UTC](https://www.wago.community/t/opcua-datasource-setup-in-codesys-error-in-opc-ua-call-badcommunicationerror/2111 "2025-08-04T08:11:58Z")

</div>

Hi all, I am trying to Configure a Datasource in Codesys 3.5 SP 19 Patch 7. I am able to connect and browse through a OPC UA server during initial configuration. But the minute I download to the PLC. I see a bunch of er…

---

## [Wbm/runtime and visualization login](https://www.wago.community/t/wbm-runtime-and-visualization-login/1056)

<div class="topic-metadata">

**Author:** [@Rafael](https://www.wago.community/u/Rafael)\
**Replies:** 10\
**Last updated:** [April 15, 2025, 7:24am UTC](https://www.wago.community/t/wbm-runtime-and-visualization-login/1056 "2025-04-15T07:24:08Z")

</div>

Hello everyone, I’m trying to understand if it is this way or I can change it. I’m making a PLC code and visualization screens, the ideia is to operate via webvisu some controls. So i made a code, made some screens and…

---

## [Ethernet communication with CC100/EdgeController/PFC300 via USB-interface](https://www.wago.community/t/ethernet-communication-with-cc100-edgecontroller-pfc300-via-usb-interface/1728)

<div class="topic-metadata">

**Author:** [@WagoTorgeir](https://www.wago.community/u/WagoTorgeir)\
**Replies:** 1\
**Last updated:** [April 3, 2025, 5:07pm UTC](https://www.wago.community/t/ethernet-communication-with-cc100-edgecontroller-pfc300-via-usb-interface/1728 "2025-04-03T17:07:45Z")

</div>

Ethernet communication (e.g. for commissioning) with CC100/EdgeController/PFC300 via the USB-interface requires NDIS/RNDIS-functionality on the PC. In order for the PC (at least for some PC types) to correctly detect a c…

---

## [EtherCAT Distributed Clocks](https://www.wago.community/t/ethercat-distributed-clocks/1455)

<div class="topic-metadata">

**Author:** [@czek](https://www.wago.community/u/czek)\
**Replies:** 10\
**Last updated:** [March 26, 2025, 3:41pm UTC](https://www.wago.community/t/ethercat-distributed-clocks/1455 "2025-03-26T15:41:46Z")

</div>

Configuration: CODESYS V3.5 SP19 Patch 7 WAGO Edge Controller 752-8303/8000-0002 FW27 Beckhoff EKM1101 EtherCAT Coupler 2 X Beckhoff ELM3002\_0205 2-channel analog input Are there any examples on using distributed cl…

---

## [WAGO 750-8212/025-000 CPU Stopped](https://www.wago.community/t/wago-750-8212-025-000-cpu-stopped/1645)

<div class="topic-metadata">

**Author:** [@Iwo25](https://www.wago.community/u/Iwo25)\
**Replies:** 3\
**Last updated:** [March 3, 2025, 2:45pm UTC](https://www.wago.community/t/wago-750-8212-025-000-cpu-stopped/1645 "2025-03-03T14:45:19Z")

</div>

WAGO 750-8212/025-000 CPU has stopped running. How can I clear the CPU errors and re-start the PLC?I tried reset & run button but did not run. We have Sys LED Green ON and IO LED ON Green.What PLC programming software ca…

---

## [Samba on Edge controler](https://www.wago.community/t/samba-on-edge-controler/1607)

<div class="topic-metadata">

**Author:** [@Etienne](https://www.wago.community/u/Etienne)\
**Replies:** 2\
**Last updated:** [February 25, 2025, 6:40am UTC](https://www.wago.community/t/samba-on-edge-controler/1607 "2025-02-25T06:40:38Z")

</div>

Hello everyone, Has anyone ever tried to install a samba/smb package on a FW28 edge controller? I’m going to need this feature. Do you know where I can find the ipk package for smb?

---

## [Limited dynamic image path length](https://www.wago.community/t/limited-dynamic-image-path-length/1512)

<div class="topic-metadata">

**Author:** [@Etienne](https://www.wago.community/u/Etienne)\
**Replies:** 8\
**Last updated:** [February 20, 2025, 4:01pm UTC](https://www.wago.community/t/limited-dynamic-image-path-length/1512 "2025-02-20T16:01:34Z")

</div>

Hello to the community I need to display a dynamic image on a visu page of an Edge Controler (Codesys 3.5 SP19 Patch7), so I declare a string variable (Variable ID image) that I modify with OPC\_UA. When I modify the st…

---

## [How To: WAGOController & Azure IoT Hub over MQTT with TLS](https://www.wago.community/t/how-to-wagocontroller-azure-iot-hub-over-mqtt-with-tls/1572)

<div class="topic-metadata">

**Author:** [@MRegulski](https://www.wago.community/u/MRegulski)\
**Replies:** 1\
**Last updated:** [February 18, 2025, 12:15pm UTC](https://www.wago.community/t/how-to-wagocontroller-azure-iot-hub-over-mqtt-with-tls/1572 "2025-02-18T12:15:07Z")

</div>

Hi all, I have recently faced a small challenge of generating X.509 certificates for MQTT communication between PFC controller and Azure IoT Hub. Port 1883 and regular comms cannot be used with Azure - it requires a use…

---

## [MQTT with TLS to Azure IoT Hub](https://www.wago.community/t/mqtt-with-tls-to-azure-iot-hub/1545)

<div class="topic-metadata">

**Author:** [@MRegulski](https://www.wago.community/u/MRegulski)\
**Replies:** 1\
**Last updated:** [February 12, 2025, 10:01am UTC](https://www.wago.community/t/mqtt-with-tls-to-azure-iot-hub/1545 "2025-02-12T10:01:58Z")

</div>

Hi all, I have been recently working with a customer on a secured communication between an Edge Controller and Azure IoT Hub via MQTT. By using WAGOAppCloud library and WAGO protocol FBs, we were able to configure the …

---

## [WagoAppPowerMeasurement sample app Unresolved reference when using 750-494 function blocks](https://www.wago.community/t/wagoapppowermeasurement-sample-app-unresolved-reference-when-using-750-494-function-blocks/1310)

<div class="topic-metadata">

**Author:** [@czek](https://www.wago.community/u/czek)\
**Replies:** 3\
**Last updated:** [January 27, 2025, 8:24pm UTC](https://www.wago.community/t/wagoapppowermeasurement-sample-app-unresolved-reference-when-using-750-494-function-blocks/1310 "2025-01-27T20:24:48Z")

</div>

After successful build I get the following error message when downloading: \[FATAL ERROR\] Unresolved reference: ‘FUIODRVCALCULATESLOTNUMBER’ Configuration: CODESYS V3.5 SP19 Patch 7 WAGO Edge Controller 752-8303/800…

---

## [EL6751 Unresolved References](https://www.wago.community/t/el6751-unresolved-references/1461)

<div class="topic-metadata">

**Author:** [@czek](https://www.wago.community/u/czek)\
**Replies:** 1\
**Last updated:** [January 16, 2025, 9:48pm UTC](https://www.wago.community/t/el6751-unresolved-references/1461 "2025-01-16T21:48:39Z")

</div>

Hello everyone, I am having trouble with EL6751 CANMiniDriver. After following the utilization instructions, I get the error messages unresolved reference: \[FATAL ERROR\] Unresolved reference: ‘EL6751\_AFTERREADINPUTS…

---

## [Compatible Touch Screen Panels for the Edge Controller (752-8303)?](https://www.wago.community/t/compatible-touch-screen-panels-for-the-edge-controller-752-8303/457)

<div class="topic-metadata">

**Author:** [@Jacob](https://www.wago.community/u/Jacob)\
**Replies:** 7\
**Last updated:** [January 15, 2025, 1:34pm UTC](https://www.wago.community/t/compatible-touch-screen-panels-for-the-edge-controller-752-8303/457 "2025-01-15T13:34:57Z")

</div>

Hello, Which touch screens (manufacture and model number) will work with the edge controller HDMI port?

---

## [Changing WBM Settings with Codesys Programatically](https://www.wago.community/t/changing-wbm-settings-with-codesys-programatically/1410)

<div class="topic-metadata">

**Author:** [@WagoKurt](https://www.wago.community/u/WagoKurt)\
**Replies:** 2\
**Last updated:** [December 13, 2024, 1:06pm UTC](https://www.wago.community/t/changing-wbm-settings-with-codesys-programatically/1410 "2024-12-13T13:06:37Z")

</div>

It is sometimes necessary to change device settings programmatically. For example, you would like the HMI to be able to change the PLC IP Address, or set the TimeZone. This can be done using the Codesys library WagoApp…

---

## [VisuDialogs.FileOpenSave crashing visualization with VisuDialogs 4.3.0.0](https://www.wago.community/t/visudialogs-fileopensave-crashing-visualization-with-visudialogs-4-3-0-0/1409)

<div class="topic-metadata">

**Author:** [@czek](https://www.wago.community/u/czek)\
**Replies:** 1\
**Last updated:** [December 9, 2024, 6:23pm UTC](https://www.wago.community/t/visudialogs-fileopensave-crashing-visualization-with-visudialogs-4-3-0-0/1409 "2024-12-09T18:23:26Z")

</div>

Upon trying to use the Open Dialog VisuDialogs.FileOpenSave the Visualization would crash upon trying to open the dialog. I isolated this issue to the initialization of the Visu\_fbFileListProvider object (Initialize meth…

---

## [WAGO Device REST-API WDx/WDA](https://www.wago.community/t/wago-device-rest-api-wdx-wda/1406)

<div class="topic-metadata">

**Author:** [@WagoKurt](https://www.wago.community/u/WagoKurt)\
**Replies:** 0\
**Last updated:** [December 6, 2024, 6:26pm UTC](https://www.wago.community/t/wago-device-rest-api-wdx-wda/1406 "2024-12-06T18:26:27Z")

</div>

WAGO Controllers now have a REST API that can be used to monitor and configure the device. To get started, simply point your web browser to the device, with this url path. (Replace IP with your controllers IP address) …

---

## [Edge Controller driver configuration for external touchscreen](https://www.wago.community/t/edge-controller-driver-configuration-for-external-touchscreen/1397)

<div class="topic-metadata">

**Author:** [@AdamReeve](https://www.wago.community/u/AdamReeve)\
**Replies:** 1\
**Last updated:** [December 5, 2024, 7:11am UTC](https://www.wago.community/t/edge-controller-driver-configuration-for-external-touchscreen/1397 "2024-12-05T07:11:02Z")

</div>

Does anyone know the name of the installed driver on the Edge Controller (752-8303) that handles external touchscreens via HDMI/USB? A client is trying to use a Hope Industrial touchscreen, but the calibration is off. Wh…

---

## [752-8303/8000-002 using CNC function](https://www.wago.community/t/752-8303-8000-002-using-cnc-function/1060)

<div class="topic-metadata">

**Author:** [@prcarlospena\_2024](https://www.wago.community/u/prcarlospena_2024)\
**Replies:** 2\
**Last updated:** [November 15, 2024, 9:19pm UTC](https://www.wago.community/t/752-8303-8000-002-using-cnc-function/1060 "2024-11-15T21:19:01Z")

</div>

The customer wants to build a simplified CNC with four servo axes using the Edge Controller 752-8303/8000-002 with EtherCAT master (I suggest using EtherCAT for speed). Has anyone used the CNC or SoftMotion libraries in…

---

## [Couldnt Scan Ethernet I/P device after adding EDS file](https://www.wago.community/t/couldnt-scan-ethernet-i-p-device-after-adding-eds-file/1224)

<div class="topic-metadata">

**Author:** [@umairyamin](https://www.wago.community/u/umairyamin)\
**Replies:** 0\
**Last updated:** [September 26, 2024, 6:01am UTC](https://www.wago.community/t/couldnt-scan-ethernet-i-p-device-after-adding-eds-file/1224 "2024-09-26T06:01:33Z")

</div>

Hi all, im currently uploaded EDS file for sensor named “Dx1000” and “LK-G5000”. Both sensors appear when i try to add device as shown below. But when i try to scan devices, only “LK-G5000” appeared. Can anyone tell…

---

## [Details for Login Error](https://www.wago.community/t/details-for-login-error/1181)

<div class="topic-metadata">

**Author:** [@umairyamin](https://www.wago.community/u/umairyamin)\
**Replies:** 2\
**Last updated:** [September 26, 2024, 3:41am UTC](https://www.wago.community/t/details-for-login-error/1181 "2024-09-26T03:41:19Z")

</div>

Hi all, I have been running my codesys for a while today without any problem, then suddenly this error pop out. Any idea why and how to solve it? Best regards, Umair

[Next page](https://www.wago.community/tag/edge-controller/9.md?match_all_tags=true&page=1&tags%5B%5D=edge-controller)